Ausschreibungstexte | Elementdicke in (mm) | Wärmedurchgangs-koeffizient Ug EN 673 (W/m²K), Gasfüllgrad 90% | Gesamtenergie-durchlassgrad EN 410 (%) ca. | Lichttransmissionsgrad (%) ca. |
---|---|---|---|---|
COMBI Neutral 70/35 NG | ||||
COMBI Neutral 70/35 NG -1 | 42 | 0.7 | 33 | 63 |
COMBI Neutral 70/35 NG -2 | 46 | 0.6 | 33 | 63 |
COMBI Neutral 70/35 NG -3 | 42 | 0.7 | 32 | 63 |
COMBI Neutral 70/35 NG -4 | 46 | 0.6 | 32 | 63 |
COMBI Neutral 50 | ||||
COMBI Neutral 50 -1 | 42 | 0.7 | 24 | 46 |
COMBI Neutral 50 -2 | 46 | 0.6 | 24 | 46 |
COMBI Neutral 50 -3 | 42 | 0.7 | 24 | 46 |
COMBI Neutral 50 -4 | 46 | 0.6 | 23 | 46 |
COMBI Neutral 60 | ||||
COMBI Neutral 60 -1 | 42 | 0.7 | 29 | 54 |
COMBI Neutral 60 -2 | 46 | 0.6 | 29 | 54 |
COMBI Neutral 60 -3 | 42 | 0.7 | 29 | 54 |
COMBI Neutral 60 -4 | 46 | 0.6 | 28 | 54 |
Ausschreibungstexte | Elementdicke in (mm) | Wärmedurchgangs-koeffizient Ug EN 673 (W/m²K), Gasfüllgrad 90% | Gesamtenergie-durchlassgrad EN 410 (%) ca. | Lichttransmissionsgrad (%) ca. |
---|---|---|---|---|
SELEKT 74/42 | ||||
SELEKT 74/42 -1 | 42 | 0.7 | 39 | 66 |
SELEKT 74/42 -2 | 46 | 0.6 | 39 | 66 |
SELEKT 74/42 -3 | 42 | 0.7 | 38 | 66 |
SELEKT 74/42 -4 | 46 | 0.6 | 38 | 66 |
SELEKT 70 | ||||
SELEKT 70 -1 | 42 | 0.7 | 34 | 63 |
SELEKT 70 -2 | 46 | 0.6 | 34 | 63 |
SELEKT 70 -3 | 42 | 0.7 | 33 | 63 |
SELEKT 70 -4 | 46 | 0.6 | 33 | 63 |
Ausschreibungstexte | Elementdicke in (mm) | Wärmedurchgangs-koeffizient Ug EN 673 (W/m²K), Gasfüllgrad 90% | Gesamtenergie-durchlassgrad EN 410 (%) ca. | Lichttransmissionsgrad (%) ca. |
---|---|---|---|---|
SUNSTOP Neutral 50 T | ||||
SUNSTOP Neutral 50 T -1 | 42 | 1.0 | 35 | 43 |
SUNSTOP Neutral 50 T -2 | 46 | 0.9 | 35 | 43 |
SUNSTOP Neutral 50 T -3 | 42 | 1.0 | 33 | 43 |
SUNSTOP Neutral 50 T -4 | 46 | 0.9 | 33 | 43 |
SUNSTOP Blau 50 T | ||||
SUNSTOP Blau 50 T -1 | 42 | 1.0 | 34 | 41 |
SUNSTOP Blau 50 T -2 | 46 | 0.9 | 34 | 41 |
SUNSTOP Blau 50 T -3 | 42 | 1.0 | 32 | 41 |
SUNSTOP Blau 50 T -4 | 46 | 0.9 | 32 | 41 |
SUNSTOP Blau 30 T | ||||
SUNSTOP Blau 30 T -1 | 42 | 0.9 | 21 | 25 |
SUNSTOP Blau 30 T -2 | 46 | 0.9 | 21 | 25 |
SUNSTOP Blau 30 T -3 | 42 | 0.9 | 20 | 25 |
SUNSTOP Blau 30 T -4 | 46 | 0.9 | 20 | 25 |
SUNSTOP Silber 20 T | ||||
SUNSTOP Silber 20 T -1 | 42 | 0.9 | 16 | 18 |
SUNSTOP Silber 20 T -2 | 46 | 0.8 | 16 | 18 |
SUNSTOP Silber 20 T -3 | 42 | 0.9 | 15 | 18 |
SUNSTOP Silber 20 T -4 | 46 | 0.8 | 15 | 18 |
Ausschreibungstexte | Elementdicke in (mm) | Wärmedurchgangs-koeffizient Ug EN 673 (W/m²K), Gasfüllgrad 90% | Gesamtenergie-durchlassgrad EN 410 (%) ca. | Lichttransmissionsgrad (%) ca. |
---|---|---|---|---|
SUPERSELEKT 60/27 | ||||
SUPERSELEKT 60/27 -1 | 42 | 0.7 | 26 | 52 |
SUPERSELEKT 60/27 -2 | 46 | 0.6 | 26 | 52 |
SUPERSELEKT 60/27 -3 | 42 | 0.7 | 26 | 52 |
SUPERSELEKT 60/27 -4 | 46 | 0.6 | 26 | 52 |
SUPERSELEKT 35/14 T | ||||
SUPERSELEKT 35/14 T -1 | 42 | 0.7 | 13 | 29 |
SUPERSELEKT 35/14 T -2 | 42 | 0.6 | 13 | 29 |
SUPERSELEKT 35/14 T -3 | 42 | 0.7 | 13 | 29 |
SUPERSELEKT 35/14 T -4 | 46 | 0.6 | 13 | 29 |